Nutech N6000 Online TVOC (NMOC) Analyzer
Nutech N6000 TVOC (CH4/NMOC) Online Analyzer is the state of art instrument in the world. The most important fact is that this online analytical instrument can detect the NMOC(TVOC) as low as 0.1 ppb, this detection limit can not be reached by most other instument in the world, more important thing is that, the TVOC(NMOC) exsiting in the ambient air or indoor air are in 0.5 to 100 ppb Level Range, any instrument can not reach lower detection limit is not suitable for those ambient air. N6000 is desigened with a preconcentration technology, and can contineousely TVOC (NMOC) with every 10 minutes. N6000 also has a 16 channel option, so can be used for multi points monitoring at same time.
Read More...
Nutech N6000-5D Online VOC Species (C2-C12) Analyzer
Nutech N6000-5D VOC Analyzer is the most state of art instrument for ambient VOC analysis in the world. The specially adsorption trap pre concentration design with electronic cryogenic cooler make the detection limit for most VOC compounds as low as 0.02 ppb. The detection limit of critical compounds can be achieved as Benzone < 0.05 ppb, Butene < 0.4ug/M3 (0.15 ppb), 1,3-Butadiene < 0.015 ppb, Trimethy/Benzone < 0.01 ppb. With the range of 0-300ppb or over. The compounds covering range are from C2-C12 Hydrocarbon as well as all other VOCs. The calibration Compounds will includes USEPA 57 PAMS compounds & USEPA TO-15 67 Compounds, as well as other organic Sulfer Compounds. The instrument is controlled with a PC based on Win7, Win8, or Win10 with the flow direction chart. The whole range analytical time is less than 60 min and most case is 30 min. The replicate R < 3%. THe carrier gas is controlled by a MFC, with 0-10ml/min, The communication with data output.
Read More...
Nutech N20-N20/2 Online Industrial TVOC (NMOC) Analyzer
This is the most state of art instrument in emission testing area for industrial usage. A special stable FID detector is used to obtain data with the heavy inforference of industrial exhaust gases such as moisture, particulates, high acid, base mixture etc. The heated sample inlet line with strong filter System can make FID stable without losting the TVOC Species. The hydrogen will be shut off if the FID flame is out. The detection range is from 0.05 ppm to 1000 ppm, and the range is automatically adjusted. The pression is RSD < 3%, and the testing accuricy recovery is 90-110%, The 0-4mA, 0-10V signer output can be selected as well as RS232, RS485 &Ethernet. A built in microcomputer will control the system.The size is desigend for standard momitor system.
Read More...
Turn Key VOC Preconcentrator System
Read More...
Nutech 8900 Preconcentrator
This preconcentrator has all the most advanced hardware and software than any other manufacturer of VOC preconcentrators in the market and many unique features that separate us from the competition for the analysis of EPA: TO-14 and TO-15 compounds. The advanced temperature control is one example how we can control variation under +/- 2 'C , assuring stable and accurate analysis.
Read More...
Nutech 3603 Series Autosampler
This instrument works with either the Nutech 8900 or Nutech 3551, it holds up to 16 canisters (all sizes) and Tedlar™ bags. The autosampler is a vertical design which saves valuable laboratory space and makes it easier to add and remove canisters. The canister hold plate is made in stainless steel and can be flipped up when not in use.
Read More...
Nutech 3606 Autosampler With Loop Injection
This instrument works in conjunction with the GC or GC/GCMS or independently as an automatic loop injection inlet. The 3606 holds up to 22 canisters (all sizes) and Tedlar™ bags. With the loop injection valve installed, the autosampler can also be attached directly to a GC or GCMS without the need of the 8900 Preconcentrator when analyzing concentrations exceeding 0.1 ppm. The autosampler is a vertical design which saves valuable laboratory space and makes it easier to add and remove canisters. The canister hold plate is made of stainless steel and can be flipped up when not in use.
Read More...
Nutech 2100 Series Canister Clean System

The cleanliness of the canister is very critical to the overall accuracy of the detection of TO-14 and TO-IS compounds in the sample. Canisters are reused by evacuating and refilling with nitrogen or zero air multiple times to assure previous VOCs are completely eliminated. The Nutech 2100 oven heating system maintains the canisters in a controlled temperature range upwards to 200'C. Sample temperature controlled heating strips are available.

Read More...
Nutech 2200 Dynamic Standard and Sample Dilution System
The Nutech 2200 system was designed for the end-user to either make his calibration standards from a high concentration source as well as to pressurize the sample canister, which is under vacuum, to an acceptable pressure and calculate the dilution factor. The dilutor prepares ppb level standards from ppm level certified cylinders. The dilutor can be expanded to accommodate 6 mass flow controllers blend cylinder standards with a diluent gas under equilibrium conditions for superior reproducibility. The Nutech 2200 has two separate channels, one for the standard and a second channel for the sample dilution.
Read More...
Nutech 2502 Automatic Thermal Desorption System 
The Nutech 2502 system automatically analyzes VOCs following EPA methods TO-17, TO-I and TO-2, the system handles tenax, charcoal, molecular sieve cartridges and other types of adsorbent tube cartridges. The Nutech 2502 works with all commercial GC and GC/GC/MS. Our system has a built in cryofocuser, wide range temperature control, and user-friendly software.
Read More...
Nutech 2505 Programmable Catridge Auto Cleaner 
The Nutech 2505 was designed to follow the protocol to clean and condition cartridges according to EPA methods TO-17, TO-I, TO-2 and other thermal desorption tubes. The Nutech 2505 cleans and conditions thermal desorption cartridges at different temperature ranges, handles tenax, charcoal, molecular sieve SS cartridges and many other types. The unit is completely programmable, user friendly software allowing technician to walk away while system performs cleaning cycle.
Read More...
Nutech 2600 Automatic Canister Sampling System 
The Nutech 2600 delivers a tremendous level of instrument control and an extensive compound recovery range. The system can be scaled to meet your application needs; can operate as a single channel, or be expanded into a dual channel, 16 positions canister sampler. We have built-in Windows Touch buttons, and can record/retrieve/print sample history in real time, including start/stop time. Schedule sampling times or initiate sampling events locally or using feedback from other real-time monitors. We leak check and flush to maintain low blank levels and improve sample integrity. All sampling events are easily programmed via the keypad and LCD display.
Read More...
Nutech 2602 Programmable Catridge Auto Sampler
The Nutech 2602 was designed to follow the protocol of EPA Method TO-I7, TO-I, TO-2, TO-II and other thermal desorption techniques. The Nutech 2602 has the ability to program up to eight sample events and accept a TTI signal, can program flow rates for I, 2, 4, 6, 8, 12, 24, 36. 48 hours. The system has an efficient pump that assures constant flow rates, handles Tenex SS cartridges, charcoal cartridges, molecular sieve cartridges and carbonyl sampling cartridges. The 2602 has first generation electronic control, friendly software and a large LCD display. 
Read More...
Nutech 2701 Programmable Field Canister Timer
The Nutech 270 I Canister Sampling Timer is designed for canister field sampling. The unit can be set for either time integration or grab samples. The timer can be easily programed for 8 events in a 7-day period with start and stop times and works with any
Read More...
Nutech 2702 Digital Programmable Field Canister Sampler 

The Nutech 2702 Canister Sampler is designed for canister field sampling. The unit can be set for either time integration or grab samples. The Sampler can be easily programed for 8 events in a 7-day period with start and stop times and is equiped with an adjustable digital flow control. The unit attaches easily to any commercial canister.

Read More...
Sampling Canisters
Canisters are used for the collection ofTO-14 and TO-IS compounds, as well as all other air samples. The canisters are the most important part of the whole air VOC analysis. We support two types of canisters: the Sileo Can™ Air Monitoring Canisters and the TO- Can™ Air Monitoring Canisters (SUMMA® equivalent).
Read More...
Accessories
Read More...
 